Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.
2011
Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…
Anterior chamber depth measurement in teenagers. Comparison of two techniques
2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Modulation transfer function: Rigid versus foldable phakic intraocular lenses
2008
Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…
Foldable toric intraocular lens for astigmatism correction in cataract patients.
2007
PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…
Intraocular lens centration and stability: efficacy of current technique and technology
2008
Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…
Compression forces of haptics of freely rotating posterior chamber intraocular lenses.
1998
Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…
The "sandwich technique" for iris-fixated phakic intraocular lens implantation.
2006
ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]